SVmco User Guidel
10
Change PSA-to-MMB LAN settings only after SVmco installation. If
changed before SVmco installation, the settings are overwritten by the
installation.
If [Interface] of [MMB-PSA IP Address] in the [Network Configuration] -
[Network Interface] window of the MMB Web-UI is Disable, you can use
event notification function of SVmco. After changing it from Disable to
Enable, the OS must be restarted.
Confirming the NIC of the PSA-to-MMB communication LAN
Confirm the interface name is assigned to the NIC of the PSA-to-MMB
communication LAN by using the following procedure.
Operations
1.
Execute the ifconfig command to confirm the interface name. This
command lists the network interfaces recognized by the system.
Syntax
/sbin/ifconfig -a
Example of output
eth0, eth1, and lo shown on the left side are the interface names.
# /sbin/ifconfig -a
eth0 Link encap:Ethernet HWaddr 00:D0:B7:53:89:C3
inet addr:10.24.17.149 Bcast:10.24.17.255