SVmco User Guidel
690
Action:
(R/M/T/S)
18505
SV RAID:%2 Adapter error (BBU communication error) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
An error occurred in communication with the BBU.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Replace the BBU. If the error recurs, replace the possibly faulty component of
the SAS interface system.
Severity:
Error
Action:
(R/M/T/S)
18506
SV RAID:%2 Adapter error (BBU failed) vendor-id=1000/1734 device-id=%d
revision=%r
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...
Страница 219: ...SVmco User Guide 211 1 Confirm that the PSA MMB_LAN chain has been created sbin iptables L ...