SVmco User Guidel
150
This section describes how to replace hard disks in a Hardware RAID
configuration. Monitor HardRAID with ServerView RAID. For details on how to replace
hard disks in a Hardware RAID configuration, see the
MegaRAID SAS User's Guide.
4.3.1.
Hot replacement of a faulty hard disk
This section describes the workflow for replacing a faulty hard disk.
1.
Start ServerView RAID Manager.
2.
In the ServerView RAID Manager tree view, confirm the mounting
location of the faulty hard disk.
* A field engineer performs steps 4 to 6 as the hard disk recovery
procedure.
3.
Confirm that the Alarm LED of the hard disk on the main unit of the
server is on.
4.
Replace the hard disk whose Alarm LED is on.
5.
In the SVOM Web-UI, open the window for the partition. Select [Driver
Monitor] from the left menu. The window displays "Error" or "Warning" at
[Status] for the array controller card that manages the faulty hard disk.
Select the card. Then, click the [Acknoledge] button.