SVmco User Guidel
868
Corrective action:
If the target logical drive is degraded, replace the HDD, and perform a rebuild.
If the target logical drive is offline, take corrective action according to the multi-
dead recovery procedure.
Severity:
Info
Action:
(R/M/T/S)
28576
SV RAID:%2 Adapter error (Internal hardware error) vendor-id=1000/1734
device-id=%d revision=%r
Meaning:
An error was detected on the SAS array controller card.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Replace the SAS array controller card.
Severity:
Error
Action: