SVmco User Guide
697
Severity:
Error
Action:
(R/M/T/S)
18516
SV RAID:%2 Adapter error (BBU temperature problem detected) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
An abnormal battery temperature was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView. If a fan failure occurred, take corrective
action for the target unit. If no fan failure occurred, recheck the environment
temperature. If the error recurs after you rechecked the environment
temperature, replace the BBU.
Severity:
Error
Action:
(R/M/T/S)