SVmco User Guidel
520
Corrective action:
The HBA must be replaced. If the problem persists even after you replace the
HBA, replace the device (e.g., PCI_Box) connected to the HBA.
Severity:
Warning
Action:
(R/M/T/S)
13122
mptscsih:iocx Adapter error (couldn't read pci register) vendor-id=1000
device-id=%d revision=%r
Meaning:
Reading of the PCI status register failed.
%d: (Example) 0030
%r: Numerical value (1 to 3 digits)
Corrective action:
The HBA must be replaced. If the problem persists even after you replace the
HBA, replace the device (e.g., PCI_Box) connected to the HBA.
Severity:
Warning
Action:
(R/M/T/S)