SVmco User Guidel
178
5.3.3.
NIC addition procedure
Referring to
5.2 Common Hot Plugging Procedure for PCI card
, add a NIC.
5.4.
FC Card Hot Plugging
For FC card hot plugging (replacement), you need to especially consider other
matters in addition to the procedure described in
5.2 PCI Card Hot Plugging
Common Procedure for PCI card
.
The hot plugging of an FC card changes the WWN of the FC card if the WWN is
set on an FC switch or RAID device (ETERNUS). For details on how to set the
WWN again for a new card, see the respective device manuals.
This section describes hot plugging of an FC card combined with ETERNUS
MPD (multipath driver).
For details on the fjpciswap command, see
3.6 PCI Card Operation Command
(fjpciswap)
.
Notes
SAN boot paths are not valid.
LTO library devices are not supported.
Depending on the Windows specifications, if the FC card connection
destination has a Page File or other such paging scheme, FC card hot
plugging may not be supported.
The error message "Source: SVagent, ID: 25004" may be output to the
event log during the replacement procedure. This message does not
indicate any problem.
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...
Страница 219: ...SVmco User Guide 211 1 Confirm that the PSA MMB_LAN chain has been created sbin iptables L ...