SVmco User Guidel
152
1.
Back up data in all the hard disks under the array controller card that are
subject to preventive replacement.
2.
Start ServerView RAID Manager.
3.
In ServerView RAID Manager, confirm the mounting location by
selecting the hard disk that S.M.A.R.T. predicted to fail.
4.
Check whether other hard disks are faulty. If a hard disk is faulty,
replace it.
5.
Restart the partition. Then, start WebBIOS from the [BIOS] window.
6.
In WebBIOS, select the array controller card connected to the hard disk
subject to preventive replacement. Then, execute [Clear Configuration] to
erase the data on the hard disk.
7.
When the data has been erased, exit WebBIOS and power off the
partition.
* A field engineer performs step 7 as the hard disk recovery procedure.
8.
Replace the hard disk that S.M.A.R.T. predicted to fail.
9.
Start the partition. Then, start WebBIOS from the [BIOS] window.
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...