SVmco User Guidel
430
An HBA reset was tried after a parity error was detected, but the operation ran
out of retries. The HBA is blocked.
(PC error recovery)
%d: device id (e.g., F980)
%r: Numerical value (1 to 3 digits)
Corrective action:
An HBA or a PCI bus in the system has a fault. Replace the adapter.
Severity:
Warning
Action:
(R/M/T/S)
12070
lpfc:xxxx:xx:xx.x Adapter error (Adapter reset failed) vendor-id=10DF
device-id=%d revision=%r
Meaning:
When a PCI error was detected, HBA Reset was executed, but it failed. (PC
error recovery)
%d: device id (e.g., F980)
%r: Numerical value (1 to 3 digits)
Corrective action:
The HBA must be replaced because it has a fault. Contact your sales
representative or a field engineer.