5.3.2.
Hot plugging a non-redundant NIC
This section describes the hot plugging procedure in networks without
redundancy (a NIC is not incorporated into teaming).
1.
Confirm the physical location by using the display function of the
fjpciswap command. Here, replace IOB#1-PCIC#5.
C:\>fjpciswap -l
Replaceable PCI cards are displayed
UnitName
Func
DeviceName
IOB#1-PCIC#5
FUNC#0
Intel(R) PRO/1000 PT Dual Port
Server Adapter #15
IOB#1-PCIC#5
FUNC#1
Intel(R) PRO/1000 PT Dual Port
Server Adapter #16
C:\>