SVmco User Guidel
866
Corrective action:
If the target logical drive is degraded, replace the HDD, and perform a rebuild.
If the target logical drive is offline, take corrective action according to the multi-
dead recovery procedure.
Severity:
Error
Action:
(R/M/T/S)
28573
SV RAID:%2 Device error (Adapter cache pinned for missing or offline
logical drives)
Meaning:
For the missing logical drives, the cached data of the SAS array controller card
has been saved.
%2: Device name
Corrective action:
If the target logical drive is degraded, replace the HDD, and perform a rebuild.
If the target logical drive is offline, take corrective action according to the multi-
dead recovery procedure.
Severity:
Error
Action: