SVmco User Guidel
734
Action:
(R/M/T/S)
18573
SV RAID:%2 Device error (Adapter cache pinned for missing or offline
logical drives)
Meaning:
For the missing logical drives, the cached data of the SAS array controller card
has been saved.
%2: Device name
Corrective action:
If the target logical drive is degraded, replace the HDD, and perform a rebuild. If
the target logical drive is offline, take corrective action according to the multi-
dead recovery procedure.
Severity:
Error
Action:
(R/M/T/S)
18574
SV RAID:%2 Device error (Adapter cache discarded by user for missing
logical drives)
Meaning:
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...
Страница 219: ...SVmco User Guide 211 1 Confirm that the PSA MMB_LAN chain has been created sbin iptables L ...