SVmco User Guidel
854
28554
SV RAID:%2 Device error (State change on disk from hot spare to failed)
Meaning:
Replace the dead HDD. Set HotSpare.
%2: Device name
Corrective action:
Replace the dead HDD. Set HotSpare.
Severity:
Error
Action:
(R/M/T/S)
28555
SV RAID:%2 Device error (State change on disk from rebuilding to failed)
Meaning:
Replace the dead HDD. Perform a rebuild.
%2: Device name
Corrective action:
Replace the dead HDD. Perform a rebuild.
Severity:
Error
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...
Страница 219: ...SVmco User Guide 211 1 Confirm that the PSA MMB_LAN chain has been created sbin iptables L ...