SVmco User Guide
653
Review the system configuration. Reduce the system load.
Severity:
Warning
Action:
( / /T/S)
14162
st:st[0-9]* Device error vendor=%v model=%m
Meaning:
A No Sense error occurred in the device. The return value from the HBA is
displayed as is.
%v: (Example) FUJITSU
%m: (Example) MAP3367NC
Corrective action:
Check the sense key included in the message. Take corrective action as
described below, according to the character string of the sense key.
For "No Sense," "Recovered Error," or "Unit Attention":
>> If the error occurred alone, no action is necessary. If the error has
occurred repeatedly, collect the data for investigation (dump or fjsnap),
and contact your sales representative or a field engineer.
For "Medium Error":
>> Replace the disk or tape.
For "Blank Check":