SVmco User Guide
47
After completing the above network settings for the management LAN, perform
the operations in
2.2.5 Setting the management LAN IP address
.
Note
In the PRIMEQUEST environment, it is necessary to specify OFF for the STP
function of the switch that connects to the management LAN used for
communication with the MMB.
2.2.3 Installing the PSHED Plugin driver
The PSHED Plugin driver expands the WHEA (Windows Hardware Error
Architecture) functions.
This driver is not automatically installed. Manually install the driver with the batch
file (plugin_install.bat) stored in the following folder.
SVmco installation folder
\fjpsaplg\plugin_install.bat
(Example: C:\Program Files (x86)\Fujitsu\ServerView
Suite\SVmco\fjpsaplg\plugin_install.bat)
Remarks
The following functions do not work unless the driver is installed:
Suppression of logging of Correctable Error events to the Event Viewer
(Windows system event log)
State transition to Stop Error for a Blue Screen of Death event ([System
Progress] in the [Power Control] window of the MMB Web-UI)
Notes