SVmco User Guide
145
Turn off the Fault LED by executing the following disk management
command.
# /opt/fujitsu/SVmco/bin/diskctrl -c ioc0/2
Note
If there is an SSD, removing the SSD may output the W13139
message from SVagent to the system event log.
Confirm the location of the inserted hard disk by displaying the status with
the disk management command.
# /opt/fujitsu/SVmco/bin/diskctrl -l
ioc0
0 /dev/sda
Fault LED-Off
1 /dev/sdb
Fault LED-Off
2 /dev/sdc
Fault LED-Off
3 /dev/sdd
Fault LED-Off
6.
After the disk management command is completed, mount the disk
partitions. If the disk has the Mirror configuration in PRIMECLUSTER GDS,
incorporate it in PRIMECLUSTER GDS.
7.
To restore each raw device, take action as follows.
o
If the hard disk had contained a raw device:
Содержание PRIMEQUEST 1000 Series
Страница 8: ......
Страница 180: ...SVmco User Guidel 172 Teaming tab ...
Страница 203: ...SVmco User Guide 195 5 Click the Sessions tab in the Properties window and click the MCS button Properties window ...
Страница 219: ...SVmco User Guide 211 1 Confirm that the PSA MMB_LAN chain has been created sbin iptables L ...