Instruction Model
e200z3 Power Architecture Core Reference Manual, Rev. 2
3-28
Freescale Semiconductor
X
011111
10100 01000 0
subfeo
Subtract From Extended with CA and record OV
X
011111
10100 01000 1
subfeo.
Subtract From Extended with CA and record OV and CR
D
001000
––––– ––––– –
subfic
Subtract From Immediate Carrying
X
011111
00111 01000 0
subfme
Subtract From Minus One Extended with CA
X
011111
00111 01000 1
subfme.
Subtract From Minus One Extended with CA and record CR
X
011111
10111 01000 0
subfmeo
Subtract From Minus One Extended with CA and record OV
X
011111
10111 01000 1
subfmeo.
Subtract From Minus One Extended with CA and record OV and CR
X
011111
10001 01000 0
subfo
Subtract From and record OV
X
011111
10001 01000 1
subfo.
Subtract From and record OV and CR
X
011111
00110 01000 0
subfze
Subtract From Zero Extended with CA
X
011111
00110 01000 1
subfze.
Subtract From Zero Extended with CA and record CR
X
011111
10110 01000 0
subfzeo
Subtract From Zero Extended with CA and record OV
X
011111
10110 01000 1
subfzeo.
Subtract From Zero Extended with CA and record OV and CR
X
011111
11000 10010 /
tlbivax
TLB Invalidate Virtual Address Indexed
X
011111
11101 10010 /
tlbre
TLB Read Entry
X
011111
11100 10010 /
tlbsx
TLB Search Indexed
X
011111
10001 10110 /
tlbsync
TLB Synchronize
X
011111
11110 10010 /
tlbwe
TLB Write Entry
X
011111
00000 00100 /
tw
Trap Word
D
000011
––––– ––––– –
twi
Trap Word Immediate
X
011111
00100 00011 /
wrtee
Write External Enable
X
011111
00101 00011 /
wrteei
Write External Enable Immediate
X
011111
01001 11100 0
xor
XOR
X
011111
01001 11100 1
xor.
XOR and record CR
Table 3-11. Instructions Sorted by Mnemonic (continued)
Format
Opcode
Mnemonic
Instruction
Primary
(Inst
0:5
)
Extended
(Inst
21:31
)
Legend:
-
Don’t care, usually part of an operand field
/
Reserved bit, invalid instruction form if encoded as 1
?
Allocated for implementation-dependent use.
Содержание e200z3
Страница 1: ...e200z3 Power Architecture Core Reference Manual Supports e200z3 e200z335 e200z3coreRM Rev 2 06 2008 ...
Страница 32: ...e200z3 Power Architecture Core Reference Manual Rev 2 xii Freescale Semiconductor ...
Страница 50: ...Register Model e200z3 Power Architecture Core Reference Manual Rev 2 2 2 Freescale Semiconductor ...
Страница 238: ...Memory Management Unit e200z3 Power Architecture Core Reference Manual Rev 2 5 16 Freescale Semiconductor ...
Страница 332: ...Power Management e200z3 Power Architecture Core Reference Manual Rev 2 8 4 Freescale Semiconductor ...