OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
2-24
Creating a List of Sequential IDs
The tester includes templates for creating a list of
sequential fiber IDs. Three of these templates meet the
ANSI/TIA/EIA-606-A standard for documenting cabling
installations, as summarized in the next section. A fourth
template lets you create your own ID pattern.
Letters and numbers in sequential IDs increment from
right to left. Special characters, accented letters, and
matching letters do not increment. For example, the
following start and stop IDs could be used for testing the
cabling in two rooms where each room has three cable
drops:
Start ID: ROOM A DROP#1
Stop ID: ROOM B DROP#3
These IDs produce the following ID list:
ROOM A DROP#1
ROOM A DROP#2
ROOM A DROP#3
ROOM B DROP#1
ROOM B DROP#2
ROOM B DROP#3
To create a list of sequential IDs, do the following:
1
Select
AUTO SEQ TEMPLATE
from the
Job
tab in
Setup, press
A
Change Template
; then select a
template.
2
Press
D
Default
to transfer the pattern to the
START ID
and
STOP ID
.
3
Press
B
Edit Start
or
C
Edit Stop
to enter
appropriate characters into the start and stop IDs.
Press
s
when you are finished editing each ID.
4
To preview the list, press
E
Sample List
.
5
Press
s
when you are finished.
The sequential ID list is stored in the mainframe (not on
the memory card or in the module).
To use an ID from the list, do the following:
1
Run a test; then press
s
.
2
Press
C
Auto Seq IDs
to select the list. You may
need to press
A
Pick ID
first.
3
Highlight an ID; then press
s
.
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...