![Fluke OF-500 OptiFiber Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/fluke/of-500-optifiber/of-500-optifiber_technical-reference-handbook_2309946216.webp)
OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
10-6
Table 10-2. Custom Limit Settings for OTDR Tests
Setting Description*
Length
Enter a maximum length for the cabling.
Reflective Event Loss
Enter a maximum value for connector loss. A typical value is 0.75 dB.
Non-reflective Event Loss
Enter a maximum value for splice loss. A typical value is 0.3 dB.
Overall Loss
Enter a maximum value for the loss of all components and fiber in the cabling. You
may also enter a minimum loss value if receiver saturation is an issue in the
installation.
Segment Attenuation Coeff
Enter a maximum value of attenuation per kilometer for a fiber segment in the
cabling.
Note
The segment attenuation coefficient for shorter segments (50 m to 500 m,
depending on wavelength and fiber characteristics) may not be measurable.
Overall Attenuation Coeff
Enter a maximum value of attenuation per kilometer for the entire length of the
cabling.
Event Reflectance
Enter a maximum reflection value for a single event.
*
Minimum values are usually not used, but are available for special situations.
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...