OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
10-4
Creating Custom Test Limits
You can create up to 10 custom test limits. Each custom
limit can include up to 5 fiber types.
1
Press
F
; then select
Edit Custom Test Limit
.
2
On the
CUSTOM LIMIT LIST
screen, do one of the
following:
•
Select an existing custom limit to edit.
•
Press
A
Add Limit
to select any existing limit as
a baseline for a new limit.
Note
When you add a new limit, 3 generic fiber types
are placed in the new limit by default.
3
Use the
LIMIT TABLE EDITOR
screen to see or define
test parameters for the fiber types you will test.
Figure 10-3 shows an example of this screen.
•
To see the properties of a factory-installed fiber
type or to edit the properties of a custom fiber
type already used in the limit, use
KNLM
to
highlight a fiber type; then press
t
.
Note
Selecting a factory-installed fiber type lets you
see the fiber’s properties, but you cannot edit
them.
•
To add a fiber type to the custom limit press
A
Add Fiber Type
; then select a fiber type from the
list or press
A
Create Fiber Type
to create a
new type. See the previous section for details on
fiber properties.
•
To remove a fiber type, highlight the fiber; then
press
B
Remove Fiber Type
.
4
To add or edit test parameters, use
KNLM
to
highlight a limit cell in the table; then press
t
.
Tables 10-2 and 10-3 describe the parameters
available for OTDR and loss/length test limits. It is not
necessary to enter test parameters for tests you will
not run.
5
When you are finished entering test parameters on
the
LIMIT TABLE EDITOR
screen, do one of the
following:
•
To save the custom limit using the existing limit
name, press
s
.
•
To edit the name, press
E
Edit Name
. Press
s
when
you are finished entering a limit
name; then press
s
again to save the limit.
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...