![Fluke OF-500 OptiFiber Скачать руководство пользователя страница 150](http://html.mh-extra.com/html/fluke/of-500-optifiber/of-500-optifiber_technical-reference-handbook_2309946150.webp)
OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
6-6
Verifying Operation
When you install the loss/length module in the tester, the
module’s model number should show in the upper-right
corner of the screen. If the screen shows
No Module
Installed
, refer to “If Something Seems Wrong” in
Chapter 10.
Loss/Length Test Settings
Table 6-1 summarizes the loss/length test settings. To
access these settings, press
S
.
Table 6-1. Loss/Length Test Settings
SETUP Tab
Setting
Description
Job
tab
Job settings
The job settings are saved with test results to identify the job site, the cables tested,
and the test direction. Before you run a test you will save, verify that the job and
fiber ID information is correct. See Chapter 2 for details.
Cable
tab
FIBER TYPE
Select a fiber type that is appropriate for the type you will test. You can select
factory-installed fiber types or custom types, which you configure with the
Edit
Custom Test Limit
function in
FUNCTIONS
. See Chapter 9 for information on creating
custom fiber types.
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...