Using the Loss/Length Option
Diagnosing Loss/Length Test Failures
6
6-41
Table 6-10. Diagnosing Loss/Length Test Failures
Loss is more than expected or is reported as “Too High”.
•
The fibers are connected to the wrong ports on the tester, or are swapped at one end of the cabling.
•
A reference test cord is broken.
•
There is one or more dirty, damaged, misaligned, or unseated connections in the cabling. Check all connections and
clean all fiber endfaces, then retest. Or use the OTDR locate bad connections.
Tip:
An OTDR cannot measure the loss of the first and last connections in the cabling unless you use a launch and
receive fiber during the OTDR test. If the first or last connection is bad, and you do not use launch and receive
fibers, the OTDR test may pass because it does include the loss of the bad connection. See “About Launch and
Receive Fibers” in Chapter 3 for details.
•
The number of adapters or splices on the
Cable
tab in Setup is too low (for limits that use a calculated loss value).
•
The wrong fiber type is selected on the
Cable
tab in Setup.
•
The reference is incorrect. Set the reference again using the same reference test cords to be used for testing.
•
A reference test cord or fiber segment has the wrong core size. If the reference test cords are the correct type, use the
OTDR to look for mismatched fiber in the cabling.
•
The cabling has a bad fusion or mechanical splice or a sharp bend. Use the OTDR to locate these faults.
W
Caution
Disconnect the source before connecting the OTDR to the cabling. Live sources can damage the OTDR’s receiver.
-continued-
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...