OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
2-8
Viewing Test Limits
To see the values of a test limit that includes the fiber
type selected on the
Cable
tab, do the following:
1
Press
S
; then select a test’s tab.
2
Select
TEST LIMIT
.
3
Highlight a limit on the
SET TEST LIMIT
screen; then
press
A
View Limit.
If the Test Limit or Fiber Type is Not Valid with the
Test
•
The fiber type was changed on the
Cable
tab in
Setup, and the current test limit does not include the
fiber type. Select a different test limit.
•
The fiber type or test limit is missing a wavelength
the test uses. For example, you are trying to run a
dual-wavelength OTDR test, but the fiber type or
limit does not include both wavelengths. Select a
different fiber type or test limit.
•
The installed module does not support the selected
fiber type or test limit. For example, a singlemode
fiber type is selected, but a multimode module is
installed. Select a different fiber type or test limit or
install a different module.
•
The test limit does not include parameters for the
type of test you are trying to run. For example, you
are trying to run an OTDR test, but only loss/length
limits are defined in the selected test limit. Select a
test limit that includes limits for the test you want to
run.
If you selected a custom fiber type or limit, you could also
edit the fiber type or limit to make it valid with the test.
See Chapter 10 for details.
Entering Job Settings
Job settings let you identify and organize the test results
you save. To access the job settings press
S
. Table 2-2
describes the job settings.
See “Tutorial: Preparing to Save Tests” on page 2-11 for
examples of how to configure the job settings.
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...