![Fluke OF-500 OptiFiber Скачать руководство пользователя страница 107](http://html.mh-extra.com/html/fluke/of-500-optifiber/of-500-optifiber_technical-reference-handbook_2309946107.webp)
Using the OTDR
Looking at OTDR Test Results
3
3-33
Table 3-4. Event Types (cont.)
Event Possible
Causes and Solutions
HIDDEN
The event is within the
attenuation deadzone of the
previous event.
The event is detected, but not enough information is available to measure its loss
separately from the previous event. Since the hidden event’s loss can’t be determined, it is
included with the loss of the previous event. This loss is displayed as "NA".
The hidden event may be a connection, a sharp bend, or a crack within the deadzone of
the previous connection.
If the event is not a connection, inspect the fiber near the event's location. Use a visual
fault locator to reveal faults.
Also see
N/A
in Table 3-3.
GHOST
The event is a duplicate
reflection caused by light
bouncing back and forth
between connectors.
Caused by a dirty or unseated connector, highly-reflective connector, a connector with the
wrong polish, a sharp bend, or a crack in a fiber.
Find the
GHOST SOURCE
in the event table to determine where to look for the fault. The
ghost source is always before the ghost. The event table does not show ghosts that occur
after the end event.
If the ghost source is a hidden event, the tester may not identify a ghost event as a ghost.
-continued-
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...