![Fluke OF-500 OptiFiber Скачать руководство пользователя страница 141](http://html.mh-extra.com/html/fluke/of-500-optifiber/of-500-optifiber_technical-reference-handbook_2309946141.webp)
Using the FiberInspector Option
Using the Probe
5
5-5
A
The magnification indicator. Press
B
Camera
to set
the magnification to match the FiberInspector probe’s
setting (250X or 400X). The setting determines the size
of the scale used for measuring core sizes. The setting is
also stored with saved images.
B
The
Visual Quality
result is stored with saved images.
Press
C
Grade Image
to assign a
PASS
,
FAIL
, or
Not
Graded
result to the image.
C
The limit used to grade the image. Future software
releases may include limits for automatically grading
endface images. When the limit is
Manual
, press
C
Grade Image
to manually assign a grade.
D
Press
A
More
to toggle between the softkey sets.
E
Press
D
Auto Center
to quickly center the image. You
can also use the arrow keys to move the image.
F
Press
E
Still
to conserve battery life by capturing the
image and turning off the probe. In still mode you can
also use the core size scale. See “Using the Core Scale”
on page 5-8.
G
Press
C
Image Contrast
to adjust the brightness and
contrast of the image.
H
Press
D
Edit Comment
to add a comment that will be
stored with the saved image.
I
Press
E
Full Screen
to use the entire screen for the
endface image.
Figure 5-3. Fiber Inspector Screen (cont.)
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...