Table 3-6. Diagnosing OTDR Test Failures (cont.)
LARGEST EVENT fails
•
The event is a dirty or damaged connector. Check the OTDR trace or event table for high-loss reflective events.
•
A patch cord, launch fiber, or fiber segment has the wrong core size, backscatter coefficient, or mode field diameter.
If the patch cords and launch fiber are the correct type, check the OTDR trace for mismatched cable in the cabling.
•
The event is a bad fusion or mechanical splice or a sharp bend. Use the OTDR trace or event table to locate these
faults.
FIBER LENGTH fails, a known length of cabling measures too long or too short, or the distance to an event is wrong.
•
The fiber is broken or there is an open connection where the trace shows the fiber end.
•
The wrong fiber type is selected on the
Cable
tab in Setup.
•
The index of refraction needs adjustment. Change n on the
Cable
tab in Setup.
•
The wrong test limit is selected on the
OTDR
tab in Setup.
An event shows a FAIL result, but the event does not exceed any limit.
The segment before the event exceeds a limit. To see results for the segment,
C
View Details
from the
EVENT TABLE
or
the
OTDR SUMMARY
screen
Содержание OF-500 OptiFiber
Страница 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Страница 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Страница 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Страница 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Страница 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Страница 95: ...Using the OTDR Running the OTDR Test 3 3 21 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable ...
Страница 133: ...Using the ChannelMap Function Running the Test 4 4 3 ajt55f eps Figure 4 2 ChannelMap Test Connections ...
Страница 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Страница 148: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 4 ajt61f eps Figure 6 2 Changing the Connector Adapter ...
Страница 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 4 ajt03f eps Figure 7 2 Using the Visual Fault Locator ...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 261: ...Loss Test Methods Method A A 2 B B 3 ajt58f eps Figure B 1 Method A A 2 Reference and Test Connections singlemode shown ...
Страница 263: ...B 5 ajt59f eps Figure B 2 Method B A 1 Reference and Test Connections singlemode shown Loss Test Methods Method B A 1 B ...
Страница 265: ...Loss Test Methods Method C A 3 B B 7 ajt60f eps Figure B 3 Method C A 3 Reference and Test Connections singlemode shown ...
Страница 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Страница 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Страница 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...