Remote Commands
Command Summary by Function
6
6-7
Table 6-5. Output Commands (cont.)
Command Description
STBY
Puts the Calibrator in standby.
WAVE
Sets the waveforms for ac outputs.
WAVE?
Shows the waveforms of the output.
ZCOMP
Starts (2-wire or 4-wire) or deactivates impedance compensation.
ZCOMP?
Shows if impedance compensation is active and if active, which type.
Table 6-6. RS-232 Host Port Commands
Command Description
LOCAL
Puts the Calibrator into the local condition.
LOCKOUT
Puts the Calibrator into the lockout condition. This command duplicates the IEEE-488
LLO (Local Lockout) message.
REMOTE
Puts the Calibrator into the remote condition. This command duplicates the IEEE-488
REN (Remote Enable) message.
SPLSTR
Sets the serial remote mode Serial Poll response string.
SPLSTR?
Shows the string programmed for serial remote mode Serial Poll responses.
SRQSTR
Sets the serial remote mode SRQ (Service Request) response (up to 40 characters).
SRQSTR?
Shows the string programmed for Serial Mode SRQ response.
UUT_RECVB? Shows binary data from the UUT serial port as integers.
UUT_SENDB
Sends binary data to the UUT serial port as integers.
^P (<cntl>p)
Control-P character prints the serial poll string. (See SPLSTR for string format.)
^C (<cntl>c)
Control-C character clears the device.
^T (<cntl>t)
Control-T character does a group trigger.
Table 6-7. RS-232 UUT Port Commands
Command Description
UUT_FLUSH
Flush the UUT receive buffer.
UUT_RECV?
Shows data from the UUT serial port.
UUT_RECVB? Shows binary data as integers from the UUT serial port.
UUT_SEND
Sends a string to the UUT serial port.
UUT_SET
Sets the UUT serial port communication parameters and keeps them in nonvolatile
memory.
UUT_SET?
Shows the UUT serial port communication parameters contained in nonvolatile memory.
Содержание 5502A
Страница 4: ......
Страница 12: ...5502A Operators Manual xii ...
Страница 46: ...5502A Operators Manual 2 2 ...
Страница 52: ...5502A Operators Manual 2 8 ...
Страница 54: ...5502A Operators Manual 3 2 ...
Страница 70: ...5502A Operators Manual 3 18 S1 S to T to S1 gvx032 eps Figure 3 4 SETUP Softkey Menu Displays cont ...
Страница 142: ...5502A Operators Manual 4 68 ...
Страница 193: ...6 1 Chapter 6 Remote Commands Title Page Introduction 6 3 Command Summary by Function 6 3 Commands 6 10 ...
Страница 194: ...5502A Operators Manual 6 2 ...
Страница 240: ...5502A Operators Manual 7 2 ...
Страница 260: ...5502A Operators Manual 7 22 ...
Страница 261: ...8 1 Chapter 8 Accessories Title Page Introduction 8 3 Rack Mount Kit 8 4 IEEE 488 Interface Cable 8 4 5500A LEADS 8 4 ...
Страница 262: ...5502A Operators Manual 8 2 ...
Страница 365: ...B 1 Appendix B ASCII and IEEE 488 Bus Codes ...
Страница 366: ...5502A Operators Manual B 2 ...
Страница 368: ...5502A Operators Manual B 4 ...
Страница 378: ...5502A Operators Manual D 6 ...