Table 6-3. External Connection Command (cont.)
Command Description
RTD_TYPE?
Shows the Resistance Temperature Detector (RTD) type.
TC_REF
Sets if the internal temperature sensor or an external reference value is used for
Thermocouple (TC) outputs and measurements.
TC_REF?
Shows the source and value of the temperature that is used as a reference for
thermocouple simulation and measurement.
TC_TYPE
Sets the thermocouple (TC) temperature type.
TC_TYPE?
Shows the thermocouple (TC) type.
TSENS_TYPE
Sets temperature sensor type when output is set to a temperature with OUT command.
TSENS_TYPE? Shows the temperature sensor type.
Table 6-4. Oscilloscope Commands
Commands Description
OL_TRIP?
Shows the found condition of scope overload protection.
OUT_IMP
Sets the output impedance of the SCOPE BNC.
OUT_IMP?
Shows the output impedance of the SCOPE BNC.
RANGE
Sets the Calibrator range when in OVERLD, PULSE, or MEASZ scope modes.
SCOPE
Sets the calibrator output to an oscilloscope mode.
SCOPE?
Shows the current oscilloscope mode.
TDPULSE
Starts or deactivates the tunnel diode pulser drive for the –SC600 and –SC300 EDGE
mode.
TDPULSE?
Shows whether the tunnel diode pulser drive for the –SC600 and –SC300 EDGE mode is
active.
TLIMIT
Sets the time limit for –SC600 OVERLD mode to stay in operate.
TLIMIT?
Shows the time limit for –SC600 OVERLD mode to stay in operate.
TLIMIT_D
Sets the power-up and reset default for the time limit for –SC600 OVERLD mode to stay
in operate.
TLIMIT_D?
Shows the power-up and reset default for the time limit for –SC600 OVERLD mode to
stay in operate.
TMWAVE Selects
the
waveform for MARKER mode.
TMWAVE?
Shows the timemark waveform setting for MARKER mode.
TRIG
Sets the frequency of the signal at the TRIG BNC.
TRIG?
Shows the frequency of the signal at the TRIG BNC.
VAL?
Shows the last thermocouple value, or, for the –SC600, impedance measurement value.
VIDEOFMT
Selects the format for VIDEO mode.
VIDEOFMT?
Shows the VIDEO mode format.
VIDEOMARK
Sets the VIDEO mode line marker location.
Содержание 5502A
Страница 4: ......
Страница 12: ...5502A Operators Manual xii ...
Страница 46: ...5502A Operators Manual 2 2 ...
Страница 52: ...5502A Operators Manual 2 8 ...
Страница 54: ...5502A Operators Manual 3 2 ...
Страница 70: ...5502A Operators Manual 3 18 S1 S to T to S1 gvx032 eps Figure 3 4 SETUP Softkey Menu Displays cont ...
Страница 142: ...5502A Operators Manual 4 68 ...
Страница 193: ...6 1 Chapter 6 Remote Commands Title Page Introduction 6 3 Command Summary by Function 6 3 Commands 6 10 ...
Страница 194: ...5502A Operators Manual 6 2 ...
Страница 240: ...5502A Operators Manual 7 2 ...
Страница 260: ...5502A Operators Manual 7 22 ...
Страница 261: ...8 1 Chapter 8 Accessories Title Page Introduction 8 3 Rack Mount Kit 8 4 IEEE 488 Interface Cable 8 4 5500A LEADS 8 4 ...
Страница 262: ...5502A Operators Manual 8 2 ...
Страница 365: ...B 1 Appendix B ASCII and IEEE 488 Bus Codes ...
Страница 366: ...5502A Operators Manual B 2 ...
Страница 368: ...5502A Operators Manual B 4 ...
Страница 378: ...5502A Operators Manual D 6 ...