OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 92 of 144
H40801-5e-ID-B.doc
6.1.3. [0x22] Lock Multiple Blocks
This command locks one or more data blocks.
The supported ISO15693 Host commands depend on the different ISO15693Transponder types, they
are described in chapter
7.1.
)
Supported ISO15693 Host commands
for ISO15693
Transponders
.
Note:
This command is only available for ISO15693Transponders.
REQUEST-DATA
4
5
(6...13)
6 / (14)
7 / (15)
0x22
MODE
UID
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5
6
ISO15693
ERROR
DB-ADR-E
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
First block number to be locked. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be locked, starting at DB-ADR. The maximum number of DB-N is
255
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95.
DB-ADR-E:
Block number where the error occurred.