OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 83 of 144
H40801-5e-ID-B.doc
5.11.1. Set Output Examples
Example No. 1:
OUT1 is alternating with 4 Hz for 500 ms.
OUT2 is activated for 500 ms.
REL is unchanged
OS
OSF
OUT-TIME
0x1C00
0x0400
0x0005
Example No. 2:
The relay is being activated for 1000 ms without any effect on the other signal emitters.
OS
OSF
OUT-TIME
0x4000
0x0000
0x000A
5.12. [0x74] Get Input
With this protocol the current status of the digital inputs IN1 ... IN2 can be determined at any time.
Host
→
Reader
1
2
3
4...5
5
COM-ADR
[0x74]
CRC16
Host
←
Reader
1
2
3
4
5
6...7
7
COM-ADR
[0x74]
STATUS
1
INPUTS
CRC16
INPUTS:
Bit:
7
6
5
4
3
2
1
0
Function:
-
-
-
-
-
-
IN2
IN1
b0
digital input = inactive
2
b1
digital input = active
3
1
see ANNEX D: Index of Status Bytes
2
see 3.4. CFG2: Inputs / Outputs general
3
see 3.4. CFG2: Inputs / Outputs general