OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 80 of 144
H40801-5e-ID-B.doc
Error Conditions (1
st
Byte):
Error
Set condition
Clear condition
RF Power
LED 5
RF-HW
no RF hardware /
error during the initializa-
tion of RF power
CPU reset
OFF
ON
NOISE
noise
≥
1000 mV
noise < max level
ON
ON
|Z|
<
absolute impedance
value
<<
50 Ohm
tune antenna
ON
ON
|Z|
>
absolute impedance
value
>>
50 Ohm
tune antenna
ON
ON
Error Conditions (2
nd
Byte):
Error
Set condition
Clear condition
RF Power
LED 5
MUX
Status != OK
Status = OK
ON
ON
DAT
Status DAT=Tuning
necessary after Reader
power up
Status DAT = OK after
Reader power up
ON
ON
Note:
Status != OK (b1) will be set if the multiplexer sends an error status or if
there is no response from the multiplexer.
MODE = 0x02:
5
6
7
IZI
res
res
MODE = 0x03:
5
6
7
8
9
MUX-Status
Chn1
MUX-Status
Chn2
MUX-Status
Chn3
MUX-Status
Chn4
MUX-Status
Chn5
©
10
11
12
ª
MUX-Status
Chn6
MUX-Status
Chn7
MUX-Status
Chn8
Notes:
If the channel has not been selected the status is 0xFF. Further informations to the ID