OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 42 of 144
H40801-5e-ID-B.doc
3.10. CFG11 Read Mode Data
The parameters of the CFG11 configuration block contain Buffered Read Mode and Scan Mode set-
tings. To enable Buffered Read Mode the BRM bit in the
3.3. CFG1: Interface
must be set.
It is useful to enable “Anticollision” function in
3.7. CFG5: Anticollision
if there is more than one Trans-
ponders in the antenna field.
Byte
0
1
2
3
4
5
6
Contents
TR-DATA
0x00
TR-DATA-3
0x00
DB-ADR
0x00
Default
0x21
0x00
0x0000
Byte
7
8
9
10
11
12
13
Contents
0x00
DB-N
0x00
D-START
D-LGT
Default
0x0001
0x00
0x0004
TR-DATA:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
TIMER
ANT
Byte
Order
0
DB
SNR
SNR
b0:
no Serial Number will be stored
b1:
Serial Number will be stored
DB
b0:
no data block will be stored
b1:
data block will be stored
Byte Order
b0:
MSB first
b1:
LSB first
ANT
b0:
the number of antenna will not be stored
b1:
the number of the antenna (1-8) where the Transponder has been detected,
will be stored if a antenna multiplexer is used.
TIMER
b0:
no internal system timer
b1:
internal system timer will be active
see chapter
5.13. [0x85] Set System Timer
for details).