3.5. CFG3: RF-Interface
The parameters of the CFG3 configuration block contain global Transponder drivers and Reader set-
tings.
Byte
0
1
2
3
4
5
6
Contents
TAG-DRV
1
RF-POWER
1
0x00
0x00
0x00
0x00
Default
MR200: 0x0008
0x07
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
FU_COM
Default
0x01
TAG-DRV
1
:
Defines the Transponder types that are operated by the Reader.
Byte:
0
1
Bit:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Driver
0
0
0
0
0
0
0
0
.H
.G
0
0
.D
0
0
0
b0
⇒
Driver for the Transponder type is inactive
b1
⇒
Driver for the Transponder type is active
.D:
Driver for ISO15693
.G:
Driver for I-Code EPC
(must be released first)
.H:
Driver for I-Code UID
(must be released first)
In principle, only those Transponder drivers should be active that are used in the
actual application. Thus, the reaction time of the Reader for Transponder read- /
write-operations is reduced and the danger of a parasitic Transponder access is
minimized.
Note:
The I-Code EPC and UID Firmware must be released with the command “Set
Firmware Upgrade” first. For this you have to use the demo program ID
ISOStart and the Upgrade Code must be ordered by Feig Electronic.
1
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = [0x11].