DB-SIZE:
Number of bytes of one data block. This value depend on the specification of the Trans-
ponder manufacturer, see chapter
7.1.
)
Supported ISO15693 Host commands for
ISO15693 Transponders
.
SEC-STATUS:
Block security status of following data block. If supported by the ISO15693 transponder.
DB:
Requested data block. The block size is defined by DB-SIZE.
Notes:
•
A read from 1 block uses a Read Single Block command to the Transponder.
•
If a Transponder does not support Read Multiple Blocks commands several Read Single
Block commands are used for this Transponder.
•