OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 134 of 144
H40801-5e-ID-B.doc
ANT1...8
b0
this antenna has not read transponder data
b1
this antenna has read transponder data
Notes:
•
This command reads the same data sets until they are cleared with the
10.5. [0x32]
Clear Data Buffer
command.
•
This command is only available in the Buffered Read Mode.
•
Data are only transferred if STATUS = 0x00, 0x83, 0x84, 0x93, 0x94.
•
If STATUS = 0x83, 0x84, 0x85 the TR-DATA and DATA SETS will be always trans-
ferred.