OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 91 of 144
H40801-5e-ID-B.doc
6.1.2. [0x02] Stay Quiet
This command sets one Transponder to Quiet State.
REQUEST-DATA
4
5
6-13
0x02
MODE
UID
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b001
addressed
UID:
Read only UID of the Transponder.
Note:
•