OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 40 of 144
H40801-5e-ID-B.doc
3.9. CFG10: Trigger
The configuration blocks contains parameters for the trigger configuration.
Byte
0
1
2
3
4
5
6
Contents
TRIGGER-
MODE
TRIGGER-
USE
TRIGGER_1-HOLD-TIME
TRIGGER_2-HOLD-TIME
0x00
Default
0x0032
5sec.
0x0032
5sec.
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
TRIGGER-MODE
defines the mode of the scanner.
Bit:
7
6
5
4
3
2
1
0
Function
Trigger
0
0
0
0
0
0
Unlimited Valid
Time
Trigger:
b0:
Trigger disabled:
The Reader RF Power is on and the Reader scans all the time in BRM
Mode.
b1
:
Trigger enabled:
The Reader start the RF Power and the scan, if the trigger is activated by
the external switch.
Note
If Trigger is enabled and not activated by the external switch, the RF-
field will be switched off.
Unlimited Valid Time:
b0:
Valid Time limited to one Trigger Period:
The Valid Time (s. CFG12) is restarted with each Trigger Period and thus
not longer than one Trigger Period.
b1
:
Unlimited Valid Time:
The Valid Time (s. CFG12) is applicable for more than one Trigger Period.