OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 82 of 144
H40801-5e-ID-B.doc
OSF:
The word OSF (Output State Flash) provides the possibility to allocate its own flashing-
frequency to each output.
Bit:
15
14
13
12
11
10
9
8
Function:
REL frq
OUT2 frq
OUT1 frq
0
0
°
7
6
5
4
3
2
1
0
ª
0
0
0
0
0
0
0
0
REL-/OUT2-/OUT1-frq:
b11
1 Hz
b10
2 Hz
b01
4 Hz
b00
8 Hz
OUT-TIME:
By the values defined by “OUT-TIME”, the outputs (OUT1, OUT2, REL) can be activated for a
temporary or unlimited period.
Exceptions are the time values 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
...
...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
Notes:
•
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to the
Reader, which effects a change to the idle status after 100 ms.
•
The continuous activation is cancelled after a reset or a power failure.