OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 28 of 144
H40801-5e-ID-B.doc
S:
Number of Stop Bits
b0:
1 Stop Bit
b1:
- do not use –
Note:
•
Changing of TRANS-FORM only becomes effective after writing / saving configura-
tion block CFG1 to EEPROM and reset of the Reader.
•
Always 8 Data Bits and 1 Stop Bits should be used
TR-RESPONSE-TIME:
By means of this parameter the maximum duration for the Transponder command can be de-
fined.
The TR-RESPONSE-TIME starts after the Reader has received a new command. At the lat-
est after the TR-RESPONSE-TIME elapsed the Reader will send an answer protocol. In this
case, the current commands between Reader and Transponder are aborted. If this time is too
short the Interface Status “ 0x83 RF Communication Error“ will appear.
max. response duration
TR-RESPONSE-TIME
0...65535 * 5 ms
Note:
•
TR-RESPONSE-TIME has no effect with the protocols for Reader Configuration and the pro-
tocols for Reader Control.
•
The TR-RESPONSE Time must be < “Block Timeout” in the Host COM-Port settings.
SCAN-INTERFACE:
Selection of the communication port for Scan-Mode
Bit:
7
6
5
4
3
2
1
0
Function:
-
-
-
-
-
IF-NO
IF-NO:
Interface Number
b000:
RS232
b001:
RS485/RS422
b01x:
- do not use –
b1xx:
- do not use -