3.21. CFG40: LAN Settings, Part 1 (not used for ID ISC.MR200-A / -W)
Byte
0
1
2
3
4
5
6
Contents
IP_ADDRESS_LAN
-
-
-
Default
0xC0
0xA8
0x0A
0x0A
0x00
0x00
0x00
192
168
10
10
Byte
7
8
9
10
11
12
13
Contents
-
IP_PORT_NUMBER_LAN
-
-
-
-
Default
0x00
0x27
0x11
0x00
0x00
0x00
0x00
10001
IP_ADDRESS_LAN:
Defines the IP address for wired LAN connection. Changing of this parameter only becomes
effective after writing / saving this configuration block to EEPROM and a [0x64] System Reset
of the LAN-adapter.
IP_PORT_NUMBER:_LAN
Defines the port number for wired LAN connection. Changing of this parameter only becomes
effective after writing / saving this configuration block to EEPROM and a [0x64] System Reset
of the LAN-adapter.
Note
Changing of the LAN-Settings in CFG 40-41 is only possible if the reader hardware ver-
sion is 556/4 or higher. For older hardware versions the tool “Digi Device Discovery”
must be used.
The configuration pages CFG40-49 cannot be set to default using the command 0x83