OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 78 of 144
H40801-5e-ID-B.doc
5.9. [0x6D] Get Noise Level
The command Get Noise Level reads the actual Noise Levels from the Reader.
Host
→
Reader
1
2
3
4...5
5
COM-ADR
[0x6D]
CRC16
Host
←
Reader
1
2
3
4
5...10
11...12
12
COM-ADR
[0x6D]
STATUS
1
NOISE-LEVEL
CRC16
NOISE-LEVEL:
Byte
5...6
7...8
9...10
NOISE-LEVEL
min. NL
avg. NL
max. NL
Value min.NL, avg.NL and max.NL in mV.
1
see ANNEX D: Index of Status Bytes