OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 56 of 144
H40801-5e-ID-B.doc
Example:
Number of Selection Bits = 10 (0x0A)
Selection Mask: 0x01 0x02 0x03 0x04 0x05 0x06 ...
Selection
Bits
1
2
3
4
5
6
7
8
9
10 11 12 13 14
15 16 17 18 19 20 ...
Selection
Mask
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
...
0x01
0x02
...
Only Transponders whose serial numbers begin with
"0000 0001 00"
return an answer.
Number of Selection Bits