OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 41 of 144
H40801-5e-ID-B.doc
TRIGGER-USE
D
efines if Input 1 to Input 2 is used as a trigger. If the Input is use as a trigger you can chose
if the Trigger start or stops the operation.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
TU 2
TU 1
TU-x:
X is the input with is used as a trigger
b00
trigger not used
b01
trigger start the Reader operation
b10
trigger start the Reader operation
b11
trigger start the Reader operation if the Reader is not in operation. In case
of Reader is in operation a rising edge on the input stops the Reader Operation
TRIGGER_X-HOLD-TIME:
(1 ... 65535 * 100 ms = 100 ms ... 6553,5 sec)
The TRIGGER-HOLD-TIME defines the period in which the Reader performs inventory commands
and hold the RF Power active.