FEIG ELECTRONIC GmbH
Page 81 of 144
H40801-5e-ID-B.doc
5.11. [0x71] Set Output
The command Set Output allows activation of the outputs of the Reader.
Each output takes on the state defined by the byte OS for the period of time included in the protocol.
The flashing frequency is defined by the byte OSF. Via this protocol the outputs can be switched on or
off for the indicated period of time. If the Reader receives a command Set Output, all times that have
been active until then are overwritten by the new times included in the protocol if they are
>
0.
Host
→
Reader
1
2
3
4...5
6...7
13
COM-ADR
[0x71]
OS
OSF
°
8...9
10...11
12...13
ª
0x00
OUT-TIME
CRC16
Host
←
Reader
1
2
3
4
5...6
6
COM-ADR
[0x71]
STATUS
1
CRC16
OS:
The word OS (Output State) defines the status of the outputs (OUT1, OUT2 and REL) during
the time defined in OUT-TIME. The signal emitters can be selected single or in a group.
Bit:
15
14
13
12
11
10
9
8
Function:
REL mode
OUT2 mode
OUT1 mode
0
0
°
7
6
5
4
3
2
1
0
ª
0
0
0
0
0
0
0
0
OUT1-/OUT2-/REL-mode:
b00
UNCHANGED
OUT-TIME has no effect on the status of the output
b01
ON
output for OUT-TIME = active
b10
OFF
output for OUT-TIME = inactive
b11
FLASH
output for OUT-TIME = with OSF alternating
1
see ANNEX D: Index of Status Bytes