background image

CR950

User Manual

www.codecorp.com

YouTube.com/codecorporation

CONFIGURATION GUIDE

Configuration barcodes generated based on current firmware versions

WEB GENERATED

5-9-2017

Summary of Contents for CR950

Page 1: ...CR950 User Manual www codecorp com YouTube com codecorporation CONFIGURATION GUIDE Configuration barcodes generated based on current firmware versions WEB GENERATED 5 9 2017 ...

Page 2: ...y Default 7 A3 Suffix Tab USB Keyboard Mode Only 7 A4 Suffix Tab RS232 Mode Only 7 B1 Suffix Carriage Return RS232 Mode Only 7 B2 Suffix Carriage Return Line Feed RS232 Mode Only Default 7 B3 Suffix Line Feed RS232 Mode Only 7 B4 Erase Suffix Data 7 C1 Convert Barcode Data to Uppercase 7 C2 Convert Barcode Data to Lowercase 7 C3 Symbology Settings 7 13 Aztec On Default 7 D2 Aztec Off 7 D3 Aztec In...

Page 3: ...o QR Code On 10 B1 Micro QR Code Off Default 10 B2 Mode 1 QR Code On 10 B3 Mode 1 QR Code Off Default 10 B4 MSI Plessey Checksum On 10 C1 MSI Plessey Checksum Off Default 10 C2 MSI Plessey Checksum Stripped from Result On 10 C3 MSI Plessey Checksum Stripped from Result Off Default 10 C4 MSI Plessey Checksum Must Be Mod 10 11 10 D1 MSI Plessey Checksum Must Be Mod 10 10 10 D2 MSI Plessey On 10 D3 M...

Page 4: ...ng for Windows Default 13 C4 Keyboard Support English Keyboard Mapping for Apple 13 D1 Keyboard Support French Belgian Keyboard Mapping for Windows 13 D2 Keyboard Support French Keyboard Mapping for Windows 13 D3 Keyboard Support French Keyboard Mapping for Apple 13 D4 Keyboard Support German Keyboard Mapping for Apple 13 E1 Keyboard Support German Keyboard Mapping for Windows 13 E2 Keyboard Suppo...

Page 5: ...Interface Odd Parity 15 D1 RS232 Interface Flow Control On 15 D2 RS232 Interface Flow Control Off Default 15 D3 Enable Packet Mode 15 D4 Enable Raw Mode Default 15 E1 Enable RS 232 Serial mode Default 15 E2 Scan Delay Settings 15 16 Disable Duplicate Scan Delay Default 15 E4 Set Duplicate Scan delay to 1 Second 16 A1 Set Duplicate Scan delay to 2 Seconds 16 A2 Set Duplicate Scan delay to 3 Seconds...

Page 6: ...ngs Motion Detect Always On Motion Detection in stand Duplicate Scan Delay 0 ms Motion Detection in stand Duplicate Scan Delay 500 ms Default Enable Cell phone reading enhancement Disable Cell phone reading enhancement Default Set motion detect maximum brightness to 25 Set motion detect maximum brightness to 50 Set motion detect maximum brightness to 75 Set motion detect maximum brightness to 100 ...

Page 7: ...ffix Space Suffix Enter USB Keyboard Mode Only Default Suffix Tab USB Keyboard Mode Only Suffix Tab RS232 Mode Only Suffix Carriage Return RS232 Mode Only Suffix Carriage Return Line Feed RS232 Mode Only Default Suffix Line Feed RS232 Mode Only Erase Suffix Data Convert Barcode Data to Uppercase Convert Barcode Data to Lowercase Intentionally Blank Aztec On Default Aztec Off Aztec Inverse Normal O...

Page 8: ...Off Default Remove Codabar Start and Stop Delimiters Code 11 Checksum Stripped from Result On Default Code 11 Checksum Stripped from Result Off Default Code 11 On Code 11 Off Default Code 11 One Digit Checksum Code 11 Two Digit Checksum Default Code 128 On Default Code 128 Off Code 32 Italian Pharmacode On Code 32 Italian Pharmacode Off Default Code 39 On Default Code 39 Off Code 39 Checksum On Co...

Page 9: ... Data Matrix Mirror On Data Matrix Mirror Off Default Data Matrix Inverse and Normal On Default Data Matrix Inverse Off Data Matrix Rectangular On Default Data Matrix Rectangular Off Data Matrix Rectangular Extended On Data Matrix Rectangular Extended Off Default Hong Kong 2 of 5 On Hong Kong 2 of 5 Off Default Interleaved 2 of 5 On Default Interleaved 2 of 5 Off Interleaved 2 of 5 Checksum On Int...

Page 10: ...5 Off Default Micro PDF417 On Micro PDF417 Off Default Micro QR Code On Micro QR Code Off Default Mode 1 QR Code On Mode 1 QR Code Off Default MSI Plessey Checksum On MSI Plessey Checksum Off Default MSI Plessey Checksum Stripped from Result On MSI Plessey Checksum Stripped from Result Off Default MSI Plessey Checksum Must Be Mod 10 11 MSI Plessey Checksum Must Be Mod 10 10 MSI Plessey On MSI Ples...

Page 11: ...om 11 PDF417 On Default PDF417 Off QR Code On Default QR Code Off QR Code Standard Only Default QR Code Mirror On QR Code Mirror Off Default QR Code Inverse and Normal On QR Code Inverse Only Telepen On Telepen Off Default Output Telepen as Numeric Default Output Telepen as ASCII Trioptic On Trioptic Off Default Reverse Trioptic On Reverse Trioptic Off Default Keep Trioptic Start and Stop Delimite...

Page 12: ...UPC Supplemental On UPC Supplemental Off Default UPC E Expansion On UPC E Expansion Off Default Convert UPC A to EAN 13 Do Not Convert UPC A to EAN 13 Default Transmit UPC A Check Digit Do Not Transmit UPC A Check Digit Default Transmit UPC A Number System Do Not Transmit UPC A Number System Default Do Not Transmit UPC E Check Digit Default Transmit UPC E Number System Do Not Transmit UPC E Number...

Page 13: ...ult Transmit EAN 13 Check Digit Do Not Transmit EAN 13 Check Digit Default Intentionally Blank List Installed Languages Get Active Language Keyboard Support US English Keyboard Mapping for Windows Default Keyboard Language Settings Keyboard Support English Keyboard Mapping for Apple Keyboard Support French Belgian Keyboard Mapping for Windows Keyboard Support French Keyboard Mapping for Windows Ke...

Page 14: ...pport Spanish Latin American Keyboard Mapping for Windows Keyboard Support Spanish Keyboard Mapping for Windows Keyboard Support Spanish Keyboard Mapping for Apple Keyboard Support UK English Keyboard Mapping for Windows Keyboard Support US International Universal Keyboard Mapping for Windows Data Encoding Raw ASCII to Keyboard XML File Lookup Default Data Encoding UTF8 to Unicode Codepoint Alt Se...

Page 15: ...Interface 19200 Baud Rate RS232 Interface 38400 Baud Rate RS232 Interface 57600 Baud Rate RS232 Interface 115200 Baud Rate Default RS232 Interface 7 Data Bits RS232 Interface 8 Data Bits Default RS232 Interface 1 Stop Bit Default RS232 Interface 2 Stop Bits RS232 Interface Even Parity RS232 Interface No Parity RS232 Interface Odd Parity RS232 Interface Flow Control On RS232 Interface Flow Control ...

Page 16: ...Seconds Set Duplicate Scan delay to 3 Seconds Set Duplicate Scan delay to 5 Seconds Set Duplicate Scan delay to 10 Seconds Set Duplicate Scan delay to 30 Seconds Set Duplicate Scan delay to 1 hour Set Duplicate Scan delay to 1 day Output Reader Configuration Get Reader Parameters Intentionally Blank Reader Modem Command Settings Reset to Factory Defaults Intentionally Blank Intentionally Blank Res...