Configure device options and preferences
6.6.3
Configure
Date
Display
Not available
ProLink II
Not available
Field Communicator
Configure→Manual Setup→Info Parameters→Transmitter Info→Date
Date
provides a place to store any date you like in transmitter memory.
Date
is a static value and is not
updated by the transmitter.
Date
is not used in transmitter processing and is not required.
Procedure
Enter any desired
Date
in the form
mm/dd/yyyy
.
If you are using ProLink II, you can access a calendar tool from the Device panel to select and enter the
data. To access the calendar tool, click
Down Arrow
in the
Date
field.
6.6.4
Configure
Sensor Serial Number
Display
Not available
ProLink II
ProLink→Configuration→Sensor→Sensor S/N
Field Communicator
Configure→Manual Setup→Info Parameters→Sensor Information→Transmitter Serial Number
Sensor Serial Number
provides a place to store the serial number of the sensor component of your flowmeter
in transmitter memory.
Sensor Serial Number
is not used in transmitter processing and is not required.
Procedure
1.
Obtain the serial number from your sensor tag.
2.
Enter the serial number in the
Sensor Serial Number
field.
6.6.5
Configure
Sensor Material
Display
Not available
ProLink II
ProLink→Configuration→Sensor→Sensor Matl
Field Communicator
Configure→Manual Setup→Info Parameters→Sensor Information→Tube Wetted Material
Sensor Material
provides a place to store the type of material used for your sensor’s wetted parts in
transmitter memory.
Sensor Material
is not used in transmitter processing and is not required.
Procedure
1.
Obtain the material used for your sensor’s wetted parts from the documents shipped with your
sensor, or from a code in the sensor model number.
114
Micro Motion 9739 MVD Transmitters
Содержание Micro Motion 9739 MVD
Страница 6: ......
Страница 8: ......
Страница 30: ...Quick start with the display OFFLINE MAINT RESTORE ZERO RESTORE YES 24 Micro Motion 9739 MVD Transmitters ...
Страница 54: ......
Страница 66: ......
Страница 104: ......
Страница 122: ......
Страница 158: ......
Страница 160: ......
Страница 170: ......
Страница 182: ......
Страница 206: ......
Страница 207: ...Appendices and reference ...
Страница 208: ......
Страница 218: ......
Страница 230: ...Using the transmitter display Figure C 4 Offline menu version information 224 Micro Motion 9739 MVD Transmitters ...
Страница 231: ...Using the transmitter display Figure C 5 Offline menu configuration units and I O Configuration and Use Manual 225 ...
Страница 233: ...Using the transmitter display Figure C 7 Offline menu configuration display Configuration and Use Manual 227 ...
Страница 234: ...Using the transmitter display Figure C 8 Offline menu Simulation loop testing 228 Micro Motion 9739 MVD Transmitters ...
Страница 236: ...Using the transmitter display Figure C 10 Offline menu Zero 230 Micro Motion 9739 MVD Transmitters ...
Страница 239: ...Using ProLink II with the 9739 MVD transmitter Figure D 2 Configuration menu Configuration and Use Manual 233 ...
Страница 241: ...Using ProLink II with the 9739 MVD transmitter Figure D 4 Configuration menu continued Configuration and Use Manual 235 ...
Страница 242: ......
Страница 245: ...Using the Field Communicator with the 9739 MVD transmitter Figure E 2 Overview menu Configuration and Use Manual 239 ...