Configure device options and preferences
Restrictions
• For some alarms,
Status Alarm Severity
is not configurable.
• For some alarms,
Status Alarm Severity
can be set only to two of the three options.
Procedure
1.
Select a status alarm.
2.
Set
Status Alarm Severity
as desired.
Option
Description
Fault
Actions when alarm is detected:
• Alarm posted to Alert List
• Outputs go to configured fault action (after
Fault Timeout
has expired, if applicable)
• Digital communications go to configured
fault action (after
Fault Timeout
has expired,
if applicable)
• Status LED changes to red or yellow
(depending on alarm severity)
Actions when alarm clears:
• Outputs return to normal behavior
• Digital communications returns to normal
behavior
• Status LED changes behavior (returns to
green, may or may not flash)
Informational
Actions when alarm is detected:
• Alarm posted to Alert List
• Status LED changes to red or yellow
(depending on alarm severity)
Actions when alarm clears:
• Status LED changes behavior (returns to
green, may or may not flash)
Ignore
No action
Status alarms and options for
Status Alarm Severity
Each status alarm has a default
Status Alarm Severity
. Some status alarms can be configured for other
severity levels.
Configuration and Use Manual
109
Содержание Micro Motion 9739 MVD
Страница 6: ......
Страница 8: ......
Страница 30: ...Quick start with the display OFFLINE MAINT RESTORE ZERO RESTORE YES 24 Micro Motion 9739 MVD Transmitters ...
Страница 54: ......
Страница 66: ......
Страница 104: ......
Страница 122: ......
Страница 158: ......
Страница 160: ......
Страница 170: ......
Страница 182: ......
Страница 206: ......
Страница 207: ...Appendices and reference ...
Страница 208: ......
Страница 218: ......
Страница 230: ...Using the transmitter display Figure C 4 Offline menu version information 224 Micro Motion 9739 MVD Transmitters ...
Страница 231: ...Using the transmitter display Figure C 5 Offline menu configuration units and I O Configuration and Use Manual 225 ...
Страница 233: ...Using the transmitter display Figure C 7 Offline menu configuration display Configuration and Use Manual 227 ...
Страница 234: ...Using the transmitter display Figure C 8 Offline menu Simulation loop testing 228 Micro Motion 9739 MVD Transmitters ...
Страница 236: ...Using the transmitter display Figure C 10 Offline menu Zero 230 Micro Motion 9739 MVD Transmitters ...
Страница 239: ...Using ProLink II with the 9739 MVD transmitter Figure D 2 Configuration menu Configuration and Use Manual 233 ...
Страница 241: ...Using ProLink II with the 9739 MVD transmitter Figure D 4 Configuration menu continued Configuration and Use Manual 235 ...
Страница 242: ......
Страница 245: ...Using the Field Communicator with the 9739 MVD transmitter Figure E 2 Overview menu Configuration and Use Manual 239 ...