Electrical Operation and Maintenance Manual for Control Cabinet of EC2-S Industrial Robot
29
Fig. 3-6 Location of SER1 Port
Fig. 3-7 Definition of SER1 Port and Connection Circuit Diagram
Table 3-5 Parameters of SER1 Port
SER1 Specification (RS232)
signal
specification
follow the EIA RS232-E specification
cable length
The cable length does not exceed 20 meters (for longer
cables, please contact EFORT)
baud rate
115200 bits/sec (maximum)
cable type
multi-pole cable 0.22mm2/ WITH, shielding coverage is
higher than 90%
connector
DSUB female 9-pin connector
3
、
CAN Port