SIMS GO
57
new row.
NOTE
It is possible to select an alternative plate numbering system for report generation in the SIMS
PRO software.
Annular Plate Number
The annular plate numbers set the position of the annular plate relative to the other annular plates
in the ring. The software counts annular plates in a clockwise direction beginning at 1. It is
recommended to keep the position of annular plate 1 close to the top left-hand corner.
NOTE
The annular ring can be rotated to the required position in the SIMS PRO software.
Plate Dimensions
The maximum dimensions for the plate length and width are entered into the relevant boxes. The
plate length dimension range is from 450mm to 15500mm (17.7in to 610in), and the plate width
dimension range is from 320mm to 15500mm (12.6in to 610in).
NOTE
The longest dimension must be the length and the shortest must be the width and is
determined by the orientation of the plate.
Plate Orientation
The orientation of a plate can be set to either horizontal or vertical in reference to the tank datum.
This determines if the plate’s length position is along the X or the Y axis for track, scan, and indication
positioning:
Horizontal.
Vertical.
Figure 64: Example of horizontal plate
Figure 65: Example of a vertical plate
Содержание Floormap X
Страница 1: ...User s Manual Floormap X MFL Array Tank Floor Inspection Solution...
Страница 10: ...10 Chapter 1 Precautions and conventions...
Страница 16: ...General Precautions and Conventions 16 1 5 EU Declaration of Conformity...
Страница 19: ...19 Chapter 2 FloormapX System Overview...
Страница 35: ...35 Chapter 3 Inspection Preparation Setup and Operation...
Страница 43: ...43 Chapter 4 SIMS GO Data Acquisition Software...
Страница 69: ...69 Chapter 5 SIMS PRO...
Страница 98: ...98 Chapter 6 Troubleshooting and Maintenance...