Inspection Preparation, Setup and Operation
42
3.7
Post-inspection checklist
Out of Tank
1.
A final calibration verification scan should be performed before completing an inspection using
the FloormapX to ensure the validity of the findings and the system set up.
2.
Back-up all the gathered inspection data stored on the tablet to a USB memory stick.
3.
Store the FloormapX and all other equipment safely during transit to avoid damage to
components. Taking care to remove cables when packing system into transit case. Ensure
batteries are removed from the FloormapX when not being used.
IMPORTANT
Ensure the magnets are turned off before packing into the transit case for shipping.
REMOVE BATTERY
When the FloormapX system is powered off the battery must be removed from the right-
hand active battery slot and placed into the left-hand storage slot. The battery capacity has
a potential of discharging if left in the active slot when the system is not powered on.
In Office
1.
After completion of an inspection, we advise the following:
2.
Clean the system. Ensure all components are free from tank residue and that magnet bridge
and scanner heads of free from unwanted ferrous material.
3.
All FloormapX batteries are placed on charge and fully charged for the next inspection.
4.
The FloormapX and related equipment are stored in a safe place within advised storing
temperatures.
5.
The MFL information gathered during an inspection is transferred onto a desktop / laptop and
processed using SIMS PRO to generate the report.
Содержание Floormap X
Страница 1: ...User s Manual Floormap X MFL Array Tank Floor Inspection Solution...
Страница 10: ...10 Chapter 1 Precautions and conventions...
Страница 16: ...General Precautions and Conventions 16 1 5 EU Declaration of Conformity...
Страница 19: ...19 Chapter 2 FloormapX System Overview...
Страница 35: ...35 Chapter 3 Inspection Preparation Setup and Operation...
Страница 43: ...43 Chapter 4 SIMS GO Data Acquisition Software...
Страница 69: ...69 Chapter 5 SIMS PRO...
Страница 98: ...98 Chapter 6 Troubleshooting and Maintenance...